Feature
Model:XY-WTH1
Temperature range:-20 ° C ~ 60 ° C
Humidity range:00%~100%RH
Control accuracy:0.1 °C 0.1% RH
Detection probe:integrated sensor
Output type:relay output
Output capacity:up to 10A
Function
Product features are two main types of classification:the functions of temperature and humidity.
The function of temperature are as follows
1. The automatic identification of work mode
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode’C’.
Start temperature
2. Cooling mode
When the temperature≥Start temperature, relay conduction, red led on, refrigeration equipment begin to work;
When the temperature≤Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
3. Heating mode
When the temperature≤Start temperature, relay conduction, red led on, heating equipment begin to work;
When the temperature≥Stop temperature, relay disconnect, red led off, heating equipment stop to work;
4. Temperature correction function OFE (-10.0 ~ 10→)
The system is working for a long time and may be biased, through this function correctly, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature
1. In the running interface, Long Press ‘ TM+ ‘ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ‘ TM-‘ key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;
The humidity function is as follows
1. The automatic identification of work mode
The system automatically according to the start/stop humidity, identify work mode;
Start humidity > stop humidity, dehumidification mode’D’.
Start humidity
2. Dehumidification mode
When the humidity ≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
When the humidity ≤ Shop humidity, relay disconnect, green led off, dehumidification equipment stops to work;
3. Humidificationmode
When the humidity ≤ Start humidity, relay conduction, green led on, humidification equipment begin to work;
When the humidity ≥ Shop humidity, relay disconnect, green led off, humidification equipment stops to work;
4. Humidificationcorrection function RH (-10.0 ~ 10%)
The system is working for a long time and may be biased, through this function correctly, the actual humidity= measuring humidity + calibration value;
How to set the start/stop humidity
1. In the running interface, Long Press ‘ RH+ ‘ key more than 3 seconds, into the start humidity settings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ‘ RH-‘ key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
Package includes
1 x Module with Sensor