Model:HX-2S-D01
Overcharge voltage range:4.25-4.35v±0.05v
Size:41*16*3.5mm
Over-discharge voltage range:2.5-3.0v±0.05v
Upper limit working current:8A
Working temperature:-40—+50 °C
Upper limit instantaneous current:10A
Storage conditions:-40– +80 ° C
Quiescent current:less than 10uA
Effective life:more than 50,000 hours
Internal resistance:less than 300mΩ
Short circuit protection:can protect, disconnect load self-recovery, charge recovery
Welding point description
· B+ is connected to the battery positive pole;
· B- is connected to the negative pole of the battery;
· MB is connected to the connection point between battery 1 and battery 2;
· P+ is connected to the positive terminal of the charge/discharge terminal (the charge terminal/discharge terminal is shared);
· P- Connect the charge/discharge terminal negative (common to the charge/discharge terminal).
Package Included
3 x Battery Protection Board