Feature
Model:YYC-2S 24 kinds of commonly used functions; can control the solenoid valve, water pump, motor, lights, etc.
Input voltage:DC 5/6/12/24V optional
Output power:can control the DC within 5A or AC load
Time range:0.01 seconds ~ 999 minutes adjustable at any time
Terminal Description
1. DC +:Input positive DC power supply
2. DC -:Input negative DC power supply
3. IN +:Signal input positive
4. IN -:Signal input negative
5. NO:Normally open relay interface, the relay hanging before pull-in, after pulled shorted connect to COM
6. COM:Relay Common Interface
7. NC:Normally closed relay interface, the relay is shorted connect to COM before pull-in, after pulled hanging
Function list
P-11:Jog (offer signal to relay pull-in, the signal disappears, the relay stop)
P-12:Self-locking (offer signal to pull, give a signal again to stop relay)
P-13:Offer signal, the relay will stop automatically for A second; trigger will be invalid during the delay time
P-14:Offer signal, the relay will stop automatically for A second; trigger re-timing during the delay time
P-15:Offer signal, the relay will stop automatically for A second; trigger superimposed during the delay time
P-16:Offer signal, the relay will stop automatically for A second; trigger reset during the delay time
P-17:Offer signal, relay pull-in, input signal is disconnected, start counting time after A second power off, during the delay period offer signal again to keep output, timing stop
P-18:When power is on, the relay will pull in immediately and power will be off after A second delay; until the next power-on
P-21:Offer signal, delay A seconds, the relay pull
P-22:Offer signal, more than A seconds, the relay pull, the signal disappears, the relay stops
P-23:After the signal disappears for more than A second, the relay will be closed, the signal will disappear and the relay will stop
P-24:When the signal exceeds A second, the relay will be closed and the relay will stop after the signal disappears for more than A seconds
P-25:When the signal exceeds A second, the relay will pull in. If the signal exceeds A seconds again, the relay will stop
P-26:When the signal pull exceeds A second and stop, signal disappear and relay pull again, after A second stop
P-27:Detection of pulse signal, the relay stops; no pulse signal, the relay delay A seconds then pull; (continuous signal or signal disappear are regarded as no pulse signal)
P-28:After power on, after a second delay, the relay will be pulled until it is powered off
P-31:After power on, relay pull A seconds, off B seconds, infinite loop; power off to stop
P-32:With signal, start P-31 infinite loop; signal disappears, terminates loop
P-33:Give a signal, start P-31 infinite loop; give a signal again to terminate the loop
P-34:After the power on, the relay will pull in after A second delay and will stop after B seconds
P-35:With signal, delay A seconds later, the relay pull, after pull B seconds stop
P-36:With signal, more than A seconds, the relay pull, after pull B seconds the relay stop, the signal disappears, the timer cleared to stop
P-37:With signal, the relay automatically stop A seconds, and then timing B seconds again, duiring A + B signal trigger is invalid
P-38:With signal, the relay pull A seconds automatically stop, stop re-time after B seconds, again pull A seconds to automatically stop
Key Settings Description
Power display inch—-inch means to enter standby mode
Press the first K1, (more than 1 second effect to prevent false triggering) Display:P -11:K2 adjust the main mode, K3, K4 adjustment function
Press the second K1, the screen displays:A001:K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)
Press the third K1, the screen displays:B001:K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit)
Press the fourth K1, inch—-inch indicates that the standby state
Press K4 in standby mode to permanently turn off / on the display and switch to low power mode
Decimal point time unit Description
X.XX timing range:0.01 seconds to 9.99 seconds
XX.X timing range:0.1 seconds to 99.9 seconds
XXX timing range:1 second to 999 seconds
XXX. timing range:1 minute ~ 999 minutes
Package includes
1 x External Trigger Delay Switch Module

Additional information

Weight 0.02 kg

Reviews

Write review “External Trigger Delay Switch Touch Button Relay Signal Timer Module Board”

Your email address will not be published. Required fields are marked *


Warning: Attempt to read property "post_content" on null in /www/wwwroot/geekpaw.com/wp-content/themes/shoptimizer-child-theme/functions.php on line 714

Warning: Attempt to read property "post_content" on null in /www/wwwroot/geekpaw.com/wp-content/themes/shoptimizer-child-theme/functions.php on line 714

Shipping Methods


Payment Methods

[contact-form-7 id="230e2c7" title="Wholesale Inquiry"]