Feature
Note:This power supply can be used with Product ID:1587151 (RD6006/RD6006-W), S06A Case Product ID 1587330 (If you need to use with RD6006/RD6006-W, please select 60V)
Model:S-400-xx
Output power:400W
Output voltage:DC12/24/36/48/60V (Optional)
Input voltage:110V/220V AC
Ambient temperature:-10 ° C ~ +50 ° C
Adjustable voltage:±10%
Product size:215 x 115 x 50mm
Item:Technical Specifications
Output:DC voltage:12V:24V:36V:48V:60V
Rated current:33.3A:16.6A:11.1A:8.3A:6.6A
Rated power:399.6W:398.4W:399.6W:398.4W:396W
Ripple and noise ↘
Voltage accuracy:±1%
Output voltage adjustment range:±10%
Load Regulation
Linear adjustment rate
Input:Voltage range:90-132VAC/180-264VAC 47Hz~63Hz; 254VDC~370VDC
Efficiency (typical):>82%:>84%:>86%:>86%:>86%
Working current
Electric shock:110VAC:25A, 220VAC:50A
Start, rise, hold time:200ms, 50ms, 20ms:230VAC
Protection:Overload protection:105%-135% type:constant current output, +V0 falls to undervoltage point to cut off output, reset:power on again
Overvoltage protection:Turn off output when >=115%-145%
Undervoltage protection:Turn off output when
Short circuit protection:Close output
:Over temperature protection:RTH3:>=65°C fan starts,
=80°C off output (5V-15V)
RTH3:>=70°C fan starts,
=85°C off output (18V-48V)
Environment:Working temperature, humidity:-10°C ~+50°C, 20% ~90%RH
Storage temperature, humidity:-20°C ~+85°C, 10%~95%RH
Safety:Withstand voltage:Input-Output:1.5KVAC
Input – Enclosure:1.5KVAC
Output – Enclosure:0.5KVAC for 1 minute
Leakage current:Input-output
Leakage current:Input-output
Isolation resistance:Input-output, input-housing, output-housing:500VDC/100MΩ
Other:Size:215*115*50mm
Net reset / gross reset:874.1/936.3g
↘Ripple and noise measurement method:Use a 12mm twisted pair cable, and the terminal should be connected with 0.1uF and 47uF capacitors in parallel and measure at 20MHz bandwidth.
Efficiency is tested at an input voltage of 230VAC, rated load, and ambient temperature of 25°C.
Accuracy:Includes setting error, linear adjustment rate and load adjustment rate.
Linear Rate Test Method:Test from low voltage to high voltage at rated load.
Load regulation test method:from 0% to 100% of rated load.