Features
– 6 kinds of commonly used functions to meet the needs of more applications;
– It can control 2-way solenoid valve, pumps, motors, lights and other running freely
– Output power:it can control within 30A DC or AC load
– Time range:0.1 seconds to 999 minutes any time adjustable
Specification
Model:YYB-5
Input voltage:DC/ AC7V-27V
Time range:0.1 seconds to 999 minutes
Wiring Port Description
1. AC/DC:Input 7V~27V
2. IN1:Signal input 1 (negative trigger)
3. IN2:Signal input terminal 2 (negative trigger)
4. IN3:Signal input 3 (negative trigger)
5. NO:relay normally open interface, relay pull before the suspension, after the connection with the COM shorted
6. COM:relay common interface
7. NC:relay normally closed interface, the relay before the connection with the COM shorted, pull after the suspension
Function list
P – 1:to signal 1, relay 1 pulls to A time automatically stops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is emergency stop reset signal
P – 2:signal 1, relay 1 is pulled to A time automatically stop; relay 2 from the signal to start delay B time after the suction to C time automatically stop (this function time unit needs to be consistent)
P – 3:After power on, relay 1 pulls up to A time release, waiting for C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns endless operation endless cycle
(If the control motor is reversible can be understood as:the motor is running a period of time; stop for some time; automatically reverse for some time; stop for some time; then automatically forward;
P – 4:to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops and starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops and starts timing To B time relay 1 pull; infinite loop
(If the control motor is reversible can be understood as:press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 to stop a period of time; then automatically forward;
P – 5:to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to A time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again
(If the control motor is reversible can be understood as:press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 stop; give the signal 1;
P-6:to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2 pull; to signal 3 (limit), relay 2 stop;
(If the control motor is reversible can be understood as:press the start button 1; go to the limit 2 stop; press the start button 1 again; reverse to the limit 3 stop;
Key Settings Description
Power display inch—-inch that access to standby;
Press the first time K1, the screen shows:P-1:K2 and K3 adjustment mode
Press the second time K1, the screen shows:A001:K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)
Press the third time K1, the screen shows:B001:K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit)
Press the fourth time K1, the screen shows:C001:K2 and K3 adjust the third time C, K4 adjust the decimal point (time unit)
Press the fifth K1, display inch—-inch that entered the standby state;
For example; need to set the mode:P – 2; time:A010 B005 C006
Indicating the second mode of operation; after the signal 1; relay 1 after 10 seconds to start off; relay 2 to give the signal after delay 5 seconds after the start 1 second automatically shut down.
Decimal Time Unit Description
XX.X decimal point in the ten, timing range:0.1 seconds to 99.9 seconds
XXX no decimal point, timing range:1 second to 999 seconds
XXX. Decimal points in a single, timing range:1 minute to 999 minutes.
Package Included
1 x YYB-5 12V 24V Motor Forward Reverse Motor Speed Controller Board