Parameter
Model:XH-W1219
Control range:-50C to 110C
Control accuracy:0.1C
Measurement input:NTC10K waterproof sensor L=0.5M
High temperature alarm:-49C to 110C
Input voltage:DC 12V
Output type:relay output up to 10A
Return difference setting:0.1C to 30C
Delayed start:0-10 minutes
Temperature correction:-10C to +10C
Size:60*43*16mm (length*width*height)
How to restore factory settings
Under normal power, press and hold the + and – key for about three seconds to restore factory settings.
1. PO temperature control mode
This value must be set when the thermostat is used for the first time. If it is used for heating, it must be set to H. If it is used for cooling, it should be set to C.
2. P1 difference setting
Press the SET button for a long time to enter the internal settings, select the P1 setting, and then press the SET button again to set the hysteresis value. (The hysteresis is the difference needed when the thermostat reaches the set temperature and stops working again.)
3. P2 temperature calibration
This function is used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, this function can be used to correct. The corrected value = measured value + correction value. (If you do not control the compressor or do not need delay function, skip this item directly)
4. P4 high temperature alarm
Set the high temperature alarm value. When the real-time temperature exceeds this value, the screen will flash warning alarm.
Package included
1 X XH-W1219 dual display digital temperature controller
Additional information
Weight | 0.028 kg |
---|