Size Conversion
Inches
Centimeters
Please according to your own measurements to choose your suitable size. The tags inside the items will show in our Asian (Type) size.
Specifications
Model:SHT2000
Supply voltage:AC 110~230V Power supply frequency:50/60Hz
Temperature range:-20~60C Humidity range:0%~100%RH
Temperature measurement accuracy:0.3 C Humidity measurement accuracy:3%
Output Control:Relay Output Output Power:MAX 10A
Setting
Setting method:Start value
Setting method:Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)
Heating/cooling mode setting
Setting mode:setting (starting temperature):Press and hold the button to start the temperature flashing. Use key to set the starting temperature value.
Setting (stop temperature):Press and hold the button to stop the temperature flashing. Use to set the stop temperature value.
Heating use case:control the water heater, heat to 65 C to stop, the temperature drops back to 50 C and start heating again
The first step:heating mode, starting temperature
Step 2:Press and hold the button to start the temperature flashing. Use to set the starting temperature to 50 C.
Step 3:Press and hold the button to stop the temperature flashing. Set the stop temperature to 65 C with keys, and the setting is completed!
Refrigeration use case:use in the farm, the fan is ventilated to 26 C to stop, the temperature is raised to 30 C and the ventilation is started again.
The first step:cooling mode, starting temperature > stop temperature
Step 2:Press and hold the button to start the temperature flashing. Use to set the starting temperature to 30 C.
Step 3:Press and hold the button to stop the temperature flashing. Use to set the stop temperature to 26C. The setting is completed!
Humidification/Dehumidification Mode Settings
Setting (start humidity):Press and hold key to start the humidity value flashing. Set the humidity value by key. Set [Stop Humidity]:Press and hold key to stop the humidity value flashing, and set the humidity to stop by key value.
Humidification example:fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps
Step 1:Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH.
The second step:long press the button for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.
Dehumidification example:workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps
Step 1:Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH.
Step 2:Press and hold the button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.
Package Inlcuded
1 x SHT2000 Digital Temperature Humidity Controller AC110V 220V
1 x Sensor Cable
Additional information
Weight | 0.169 kg |
---|
Reviews