Specifications
Product model:YYI-4
Detection range:voltage:DC 7 ~ 30V, current:0 ~ 30A
Detection accuracy:0.1A (100mA)
Standby current:About 20mA
Relay output:it can control the on-off of DC line within 30A.
With error calibration function, it can turn off the display for a long time and reduce power consumption
Function Description
P-11:when the measured current is greater than I1, the relay is on; when the measured current is less than I1 again, the relay is off.
P-12:when the measured current is greater than I1, the relay is closed; it is always closed until the power supply of the circuit board is cut off.
P-21:when the measured current is greater than I2, the relay is on; when the measured current is less than I1, the relay is off
P-22:when the measured current is greater than I2, the relay is closed; it is always closed until the power supply of the circuit board is cut off.
P-31:when the measured value is less than I1, the relay is on; when the current is greater than I2, the relay is off
P-32:when the measured current is less than I1, the relay is closed; it is always closed until the power supply of the circuit board is cut off.
P-41:when the measured current is between I1 and I2, the relay is closed, and in other cases, the relay is disconnected;
P-42:when the measured current is between I1 and I2, the relay is closed; it is always closed until the power supply of the circuit board is cut off.
P-51:when the measured current is less than I1 or more than I2, the relay is closed, and in other cases, the relay is disconnected;
P-52:when the measured current is less than I1 or more than I2, the relay is closed; it is always closed until the power supply of the circuit board is cut off.
Setting Description
– Power on to display the measured current; (if the measured current end is suspended, the digital display digital runout is normal.)
– It takes more than 1 second to press K1 for the first time to prevent false triggering. The screen displays:P 11:K2 adjustment mode, K3 adjustment function.
– Press K1 for the second time, the screen flashes:0.05 means the value of threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus
– Press K1 for the third time, the screen flashes:0.10 indicates that the value of threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus
– Press K1 for the fourth time, the measured current will be displayed on the screen; it means entering the standby mode;
– Long press K2 or K3 in standby mode to fine tune the measured current error.
Package Incldued
1 x YYI-4 Current Detection Module DC Over-current Motor Locked Rotor Protection Board