Specifications
Model:KP-01
Color:Black / Blue
MaterialPlastic
Size:85*75*35mm / 3.3x3x1.4inch
Power6VDC 2 CR2032 (230mAh) lithium batteries
Battery life:About 2 years, 10 times a day
Working frequency:433.92 MHz +/-75KH
Emission power:About 1mW
Encoding formatHCS101 standard format
Working temperature:-10~+55 C
Digit number:0 to 8 bits
Launch distance:Open Distance 200 meters; indoor distance 35 meters
Protection grade:IP54
Product description
-This is a dual channel transmitters that are activated only after having entered a Suitable combination.
-The units are designed for installation in indoor or outdoor locations that ensures the utmost security because the transmitted code is changed at each transmission session.
-The estimated transmission range is 200 m in open space and 35 m indoors
-The units are designed to ensure battery life equivalent to an estimated 2 years of operation considering 10 transmissions/day
Installation
-Before physically installing the it in their mouning position it is good practice to perform a practical test to assess their functionality and effective range.
-Consider that range may be up to 25 or 30% less when battery power is low
positioning
-Apart from the distance from the receiver, the units should not be positioned in the vicinity of or-worsestill-in contact with metal structures, which could otherwise exert a signal shielding effect. Thanks to the enclosure protection rating of IP 54, the digital selectors can be installed outdoors if required.
Audible signal status
-1 short beep
-Keypad tone
-1 long beep
-Modification of combination confirmed (or send the signal after enter the correct password )
-5 short beeps
-Error during combination input or combination edit operation
-2 low beeps
-Battery low warning signal New batteries required
Method of use
-The use of the keypad is based on inchcombinationsinch, i.e. numbers of from 1 to 9 digits that the user is required to key in by means of the keys.Once the combination has been entered the user then presses confirm key3 or 4 to transmit the activation command
to respectively.
-Receiver channel 1 if the user presses3
-Receiver channel 2 if the user presses4
-The command will be transmitted only when a valid combination has been entered ,if an incorrect combination has been entered the selector will emit an error, warning signalwhen the confirom key is pressed
-The combination entered must be exact,if, for example:the correct combination is 0422, the following attempts will be interpreted as errors:422,10422, 04222
-Therefore, if the user inadvertently presses the wrong key,when entering a combination, combination key3 or 4 should be pressed immedliately to generate the error tone,after which the correct combination can be entered starting from the beginning again
-While entering the combination no more than 6 seconds can be allowed to elapse between keystrokes,after which interval the combination must be re-entered starting from the beginning.
-The units are factory programmed with a standard combination to activate channel one and a standar combination for channel two
The factory set combinations are as follows
-1a combination to transmit the code associated with the 3 key
-When the unit is used for the first time this combination is11
-2a combination to transmit the code associated with the 4 key
-When the unit is used for the first time this combination is 22
Additional information
Weight | 0.263 kg |
---|
Reviews